Livoa LogoLivoa
Core Layer - Server Room (Floor 1)


Core-FL1

Distribution Closet (Floor 2)


Dist-FL2

Distribution Closet (Floor 3)


Dist-FL3

Distribution Closet (Floor 4)


Dist-FL4

Distribution Closet (Floor 5)


Dist-FL5

Access Layer - Workstations (Floor 2)


5 Departments × 12 Workstations = 60 points

Label example: FL2-RM101-P1

Access Layer - Workstations (Floor 3)


5 Departments × 12 Workstations = 60 points

Label example: FL3-RM101-P1

Access Layer - Workstations (Floor 4)


5 Departments × 12 Workstations = 60 points

Label example: FL4-RM101-P1

Access Layer - Workstations (Floor 5)


5 Departments × 12 Workstations = 60 points

Label example: FL5-RM101-P1

Cable Types & Labeling


- Horizontal: Cat6 (up to 100m)

- Vertical Riser: Multimode Fiber

- Label format: FLx-RMy-Pz (e.g., FL2-RM101-P1)

Installation Guidelines


- Pull boxes, tension limits: Cat6 <25 lbs, Fiber <600 lbs

- Avoid sharp bends <90°

- Separate power & data cables by 12 inches

- Terminate Cat6 with RJ45, Fiber with SC/LC connectors

- Secure cables with ties

Testing & Hardware


- Racks: 42U (server room), 24U (floors)

- Patch Panels: 48-port (server), 24-port (floors)

- Faceplates: 2-port per workstation

- Patch cords: 2m Cat6

- Testing: Cable certifier for end-to-end, multi-meter for continuity

- Switches: Core - Cisco Catalyst 9300 (PoE+)

Distribution - Cisco Catalyst 3850 (PoE)

Access - Cisco Catalyst 2960 (PoE)

PBA